2XSLCY-J 0,6/1 kV

2XSLCY-J 0,6/1 kV

Electrical power cable with copper multi-wire conductors in cross-linked polyethylene insulation (2X) and external softened PVC sheath (Y), with common shield on central core in the form of an aluminium-coated tape with a braid of copper zinc-coated wires (LC), with green and yellow protective conductor (J).

CONSTRUCTION:

Conductors

copper, multi-wire, round, class 5 as per PN-EN 60228

Insulation

XLPE cross-linked polyethylene

Central core

stranded conductors

Shield

polyester tape coated with aluminium with a braid of copper zinc-coated wires

Sheath

special softened PVC, transparent

Insulation colours

black, brown, grey, green and yellow

Operating temperature

for fixed systems: -30°C to +70°C for mobile systems: -5°C to +70°C

Operating voltage

0,6/1 kV

Bend radius

diameter up to 12 mm – min. bend radius

5 x central core diameter

diameter from 12 mm to 20 – min. bend radius 

7,5 x central core diameter

diameter over 20 mm – min. bend radius

10 x central core diameter

Application

electric power cable intended for use in engines in drives using frequency converters, XLPE crosslinked polyethylene increases current capacity of the cables, double shielding meets requirements regarding electromagnetic and radio-frequency interference, cables are intended for mobile connections and fixed installations in industrial equipment, production lines, machinery operating in dry and damp rooms, also in public utility facilities

Technical parameters

capacitance:

conductor/conductor = 70 to 250 nF/km

conductor/shield = 110 to 410 nF/km

max. operating conductor temperature: 70°C

Packing

coils, drums

 

2XSLCY-J 0,6/1 kV

Number of conductors x conductor diameter

[mm]

Approximate external cable diameter

[mm]

Current capacity of a single cable in the air at 30°C

[A]

Approximate cable weight

[kg/km]

4 G 1,5

11,4

23

148

4 G 2,5

12,4

32

227

4 G 4

13,6

42

331

4 G 6

15

54

437

4 G 10

17,1

75

623

4 G 16

19,4

100

827

4 G 25

23,7

127

1332

4 G 35

26,1

158

1726

4 G 50

30,1

192

2406

4 G 70

34,8

246

3063

4 G 95

38,7

298

4169

4 G 120

42

346

5081

4 G 150

47,9

399

6135

4 G 185

53,5

456

7197

4 G 240

59,2

528

9602

Warianty / Variants (30)

IDWariantSymbolPDF
28332XSLCY-J 0,6/1kV 4G1,52XSLCY-J 0,6/1 kV
28342XSLCY-J 0,6/1kV 4G1,52XSLCY-J 0,6/1 kV
28352XSLCY-J 0,6/1kV 4G2,52XSLCY-J 0,6/1 kV
28362XSLCY-J 0,6/1kV 4G2,52XSLCY-J 0,6/1 kV
28372XSLCY-J 0,6/1kV 4G42XSLCY-J 0,6/1 kV
28382XSLCY-J 0,6/1kV 4G42XSLCY-J 0,6/1 kV
28392XSLCY-J 0,6/1kV 4G62XSLCY-J 0,6/1 kV
28402XSLCY-J 0,6/1kV 4G62XSLCY-J 0,6/1 kV
28412XSLCY-J 0,6/1kV 4G102XSLCY-J 0,6/1 kV
28422XSLCY-J 0,6/1kV 4G102XSLCY-J 0,6/1 kV
28432XSLCY-J 0,6/1kV 4G162XSLCY-J 0,6/1 kV
28442XSLCY-J 0,6/1kV 4G162XSLCY-J 0,6/1 kV
28452XSLCY-J 0,6/1kV 4G252XSLCY-J 0,6/1 kV
28462XSLCY-J 0,6/1kV 4G252XSLCY-J 0,6/1 kV
28472XSLCY-J 0,6/1kV 4G352XSLCY-J 0,6/1 kV
28482XSLCY-J 0,6/1kV 4G352XSLCY-J 0,6/1 kV
28492XSLCY-J 0,6/1kV 4G502XSLCY-J 0,6/1 kV
28502XSLCY-J 0,6/1kV 4G502XSLCY-J 0,6/1 kV
28512XSLCY-J 0,6/1kV 4G702XSLCY-J 0,6/1 kV
28522XSLCY-J 0,6/1kV 4G702XSLCY-J 0,6/1 kV
28532XSLCY-J 0,6/1kV 4G952XSLCY-J 0,6/1 kV
28542XSLCY-J 0,6/1kV 4G952XSLCY-J 0,6/1 kV
28552XSLCY-J 0,6/1kV 4G1202XSLCY-J 0,6/1 kV
28562XSLCY-J 0,6/1kV 4G1202XSLCY-J 0,6/1 kV
28572XSLCY-J 0,6/1kV 4G1502XSLCY-J 0,6/1 kV
28582XSLCY-J 0,6/1kV 4G1502XSLCY-J 0,6/1 kV
28592XSLCY-J 0,6/1kV 4G1852XSLCY-J 0,6/1 kV
28602XSLCY-J 0,6/1kV 4G1852XSLCY-J 0,6/1 kV
28612XSLCY-J 0,6/1kV 4G2402XSLCY-J 0,6/1 kV
28622XSLCY-J 0,6/1kV 4G2402XSLCY-J 0,6/1 kV

Wydruk obejmuje opis rodziny i widoczną stronę wariantów. Pełny zestaw można przeglądać kolejnymi stronami.