D; L

800x600
Normal 0 21 false false false PL X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:Standardowy; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Calibri","sans-serif"; mso-bidi-font-family:Arial;}
Bare single-strand copper conductor (D), bare multi-strand copper conductor (L).
|
CONSTRUCTION: |
|
|
Conductors |
conductors type D and L - hard copper according to PN-74 / E 90080, conductors type L - copper class 2 according to PN-EN 60228 |
|
Application |
conductors dedicated to construct overhead power lines |
|
Packing |
colis, drums |
|
D |
||
|
Number and nominal cross-section of conductor (n x mm²) |
Approximate external cable diameter (mm) |
Approximate cable weight (kg/km) |
|
1 x 4 RE |
2,24 |
35,1 |
|
1 x 6 RE |
2,74 |
52,7 |
|
1 x 10 RE |
3,56 |
87,6 |
|
Hard bare multi-strand copper conductors | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Cross-section |
Number of wires |
Diameter |
Computational breaking load |
DC resistance at 20 ° C |
Calculated mass of 1 km |
Symbol |
Catalog No. |
||
|
Rated |
Computational |
Wire rating |
Computational cable |
||||||
|
mm2 |
mm2 |
szt. |
mm |
mm |
kN |
Ω/km |
kg |
- |
- |
|
10 |
10,1 |
49 |
0,51 |
4,59 |
3,20 |
1,815 |
91 |
L10 |
9811-1 |
|
16 |
16,07 |
7 |
1,71 |
5,13 |
5,54 |
1,142 |
146 |
L16 |
- |
|
25 |
24,94 |
7 |
2,13 |
6,39 |
8,60 |
0,7361 |
226 |
L25 |
9811-2 |
|
35 |
34,91 |
7 |
2,52 |
7,56 |
12,03 |
0,5259 |
316 |
L35 |
9811-3 |
|
50 |
49,48 |
7 |
3,00 |
9,00 |
17,05 |
0,3712 |
449 |
L50 |
9811-4 |
|
70 |
70,27 |
19 |
2,17 |
10,85 |
24,22 |
0,2613 |
637 |
L70 |
9811-5 |
|
95 |
94,76 |
19 |
2,52 |
12,60 |
32,67 |
0,1938 |
859 |
L95 |
9811-6 |
|
120 |
117,0 |
19 |
2,80 |
14,00 |
40,32 |
0,1570 |
1060 |
L120 |
9811-7 |
|
150 |
148,4 |
37 |
2,26 |
15,82 |
51,15 |
0,1237 |
1345 |
L150 |
9811-8 |
|
185 |
184,5 |
37 |
2,52 |
17,64 |
63,60 |
0,0995 |
1673 |
L185 |
- |
|
240 |
241,0 |
37 |
2,88 |
20,16 |
83,07 |
0,0762 |
2185 |
L240 |
- |
|
300 |
299,4 |
61 |
2,50 |
22,50 |
97,77 |
0,0613 |
2715 |
L300 |
- |
|
Packing |
drums |
||||||||
|
Soft bare multi-strand copper conductors | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Cross-section |
Number of wires |
Diameter |
DC resistance at 20 ° C |
Calculated mass of 1 km |
Core designation class |
Symbol |
Catalog No. |
||
|
Rated |
Computational |
Wire rating |
Computational cable |
||||||
|
mm2 |
mm2 |
szt. |
mm |
mm |
Ω/km |
kg |
- |
- |
- |
|
95 |
94,2 |
37 |
1,8 |
12,60 |
0,190 |
845 |
K2 |
L 95 |
9812-6 |
|
185 |
182 |
37 |
2,5 |
14,0 |
0,097 |
1650 |
K2 |
L 185 |
9812-9 |
|
Packing |
drums |
||||||||
|
Soft bare multi-strand copper conductors | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Cross-section |
Number of wires |
Diameter |
DC resistance at 20 ° C |
Calculated mass of 1 km |
Core designation class |
Symbol |
Catalog No. |
||
|
Rated |
Computational |
Wire rating |
Computational cable |
||||||
|
mm2 |
mm2 |
szt. |
mm |
mm |
Ω/km |
kg |
- |
- |
- |
|
185 |
182 |
321 |
0,85 |
21,2 |
0,0991 |
1702 |
L2 |
L185 |
9815-9 |
|
Packing |
drums |
||||||||
Warianty / Variants (15)
| ID | Wariant | Symbol | |
|---|---|---|---|
| 2289 | L 1x10 | L | |
| 2290 | L 1x16 | L | |
| 2291 | L 1x25 | L | |
| 2292 | L 1x35 | L | |
| 2293 | L 1x50 | L | |
| 2294 | L 1x70 | L | |
| 2295 | L 1x95 | L | |
| 2296 | L 1x120 | L | |
| 2297 | L 1x150 | L | |
| 2298 | L 1x185 | L | |
| 2299 | L 1x240 | L | |
| 2300 | L 1x300 | L | |
| 28904 | D 1x6 | D | |
| 28906 | D 1x4 | D | |
| 28907 | D 1x10 | D |
Wydruk obejmuje opis rodziny i widoczną stronę wariantów. Pełny zestaw można przeglądać kolejnymi stronami.