HDXSp-J (O) 300/500V
%20450.jpg)
Single-wire copper conductors (D) in polyethylene insulation (XS) and in a halogen-free coating (H) flat (p) sheet with green-yellow protective conductor (J) or without a green-yellow protective conductor (O)
|
CONSTRUCTION: |
|
|
Conductors |
copper, single-wire, class. 1, acc. to standard PN-EN 60228 |
|
Insulation |
cross-linked polyethylene |
|
Sheath |
special halogen-free polymer compound, white colour |
|
Insulation colours |
HDXSp-O 2-conductor: blue, brown 3-conductor: brown, black, grey or blue, brown, black 4-conductor: blue, brown, black, grey HDXSp-J 3-conductor: green-yellow, blue, brown 4-conductor: yellow-green, black, brown, grey or yellow-green, blue, brown, black |
|
Operating temperature |
od -40°C do +70°C |
|
Nominal voltage |
300/500 V |
|
Minimum bending radius |
conductor outer diameter D [mm] 6xD |
|
Permissible conductor operating temperature |
+90°C |
|
Permissible conductor temperature during short circuit |
+250°C |
|
Application |
halogen-free power supply conductors for installations in facilities where human life and property must be protected against fire (hotels, hospitals, schools, airports, underground and train stations, industrial installations); conductors to be laid in dry and moist rooms, over and in plasterwork, in brick walls and directly in concrete; only permanent installation possible; in outdoor or underground installations cables must be laid in cable ducts or tubes |
|
Packing |
coils of length of 100 m and others, according to customer’s wishes |
|
HDXSp-J(O) 300/500V |
||
|
Number and nominal cross-section of conductor [n x mm²] |
Approximate outer dimension of the conductor [mm] |
Approximate cable mass [kg/km] |
|
2 x 0,5 |
3,6 x 5,4 |
29 |
|
2 x 0,75 |
3,8 x 5,7 |
36 |
|
2 x 1 |
3,9 x 6,0 |
41 |
|
2 x 1,5 |
4,2 x 6,5 |
51 |
|
2 x 2,5 |
4,6 x 7,3 |
71 |
|
2 x 4 |
5,4 x 8,8 |
107 |
|
2 x 6 |
5,9 x 9,8 |
147 |
|
3 x 0,5 |
3,6 x 7,1 |
40 |
|
3 x 0,75 |
3,8 x 7,7 |
50 |
|
3 x 1 |
3,9 x 8,2 |
58 |
|
3 x 1,5 |
4,2 x 8,9 |
74 |
|
3 x 2,5 |
4,8 x 10,3 |
109 |
|
3 x 4 |
5,4 x 12,2 |
155 |
|
3 x 6 |
5,9 x 13,7 |
224 |
|
4 x 0,5 |
3,6 x 8,9 |
51 |
|
4 x 0,75 |
3,8 x 9,7 |
64 |
|
4 x 1 |
3,9 x 10,3 |
75 |
|
4 x 1,5 |
4,4 x 11,4 |
99 |
|
4 x 2,5 |
4,8 x 13,0 |
138 |
|
4 x 4 |
5,4 x 15,6 |
215 |
|
4 x 6 |
5,9 x 17,6 |
296 |
Warianty / Variants (21)
| ID | Wariant | Symbol | |
|---|---|---|---|
| 30157 | HDXSp-O 300/500V 2x0,5 | HDXSp-J (O) 300/500V | |
| 30178 | HDXSp-O 300/500V 2x1,0 | HDXSp-J (O) 300/500V | |
| 30179 | HDXSp-O 300/500V 2x1,5 | HDXSp-J (O) 300/500V | |
| 30180 | HDXSp-O 300/500V 2x2,5 | HDXSp-J (O) 300/500V | |
| 30181 | HDXSp-O 300/500V 2x4 | HDXSp-J (O) 300/500V | |
| 30182 | HDXSp-O 300/500V 3x1,0 | HDXSp-J (O) 300/500V | |
| 30183 | HDXSp-O 300/500V 3x1,5 | HDXSp-J (O) 300/500V | |
| 30184 | HDXSp-O 300/500V 3x2,5 | HDXSp-J (O) 300/500V | |
| 30185 | HDXSp-O 300/500V 3x4 | HDXSp-J (O) 300/500V | |
| 30186 | HDXSp-O 300/500V 4x1,0 | HDXSp-J (O) 300/500V | |
| 30187 | HDXSp-O 300/500V 4x1,5 | HDXSp-J (O) 300/500V | |
| 30188 | HDXSp-O 300/500V 4x2,5 | HDXSp-J (O) 300/500V | |
| 30189 | HDXSp-O 300/500V 4x4 | HDXSp-J (O) 300/500V | |
| 30190 | HDXSp-J 300/500V 3x1,0 | HDXSp-J (O) 300/500V | |
| 30191 | HDXSp-J 300/500V 3x1,5 | HDXSp-J (O) 300/500V | |
| 30192 | HDXSp-J 300/500V 3x2,5 | HDXSp-J (O) 300/500V | |
| 30193 | HDXSp-J 300/500V 3x4 | HDXSp-J (O) 300/500V | |
| 30194 | HDXSp-J 300/500V 4x1,0 | HDXSp-J (O) 300/500V | |
| 30195 | HDXSp-J 300/500V 4x1,5 | HDXSp-J (O) 300/500V | |
| 30196 | HDXSp-J 300/500V 4x2,5 | HDXSp-J (O) 300/500V | |
| 30197 | HDXSp-J 300/500V 4x4 | HDXSp-J (O) 300/500V |
Wydruk obejmuje opis rodziny i widoczną stronę wariantów. Pełny zestaw można przeglądać kolejnymi stronami.