PARCONTROL YKSLYekwo(żo), YoKSLYekwo(żo), YcKSLYekwo(żo), YnKSLYekwo(żo), YKSLYekwo-P, YoKSLYekwo-P, YcKSLYekwo-P, YnKSLYekwo-P 0,6/1 kV

PARCONTROL YKSLYekwo(żo), YoKSLYekwo(żo), YcKSLYekwo(żo), YnKSLYekwo(żo), YKSLYekwo-P, YoKSLYekwo-P, YcKSLYekwo-P, YnKSLYekwo-P 0,6/1 kV

Signal (S) cable (K) with copper multi-wire conductors (L) in softened PVC insulation (Y) and softened PVC sheath (Y), with common shield in the form of a braid of copper zinc-coated wires (ekwo), with green and yellow protective conductor (żo) or without green and yellow protective conductor (żo) or with paired conductors (P).

CONSTRUCTION:

Conductors

copper, multi-wire, class 5 as per PN-EN 60228

Insulation

special softened PVC

Central core

YKSLYekwo(żo) – conductors stranded into a central core

YKSLYekwo-P – conductors stranded into pairs,

pairs stranded into a central core

Internal sheath

special softened PVC

Shield

braid of copper zinc-coated wires

Sheath

YLKSLYekwo(żo) – special softened PVC, black

YcKSLYekwo(żo) – special heat resistant softened PVC (Yc)

YoKSLYekwo(żo) – oil resistant softened PVC, as per

PN-EN 60811-404:2012 (Yo)

 YnKSLYekwo(żo) – special softened PVC with increased fire resistance and oxygen index of at least 29 (Yn)

Insulation colours

all conductors black with white numbers, in case there is a protective conductor – it is marked with green and yellow colour and located in the external layer

Operating temperature

-30°C to +70°C

Nominal voltage

0,6/1 kV

Bend radius

min. bend radius for flexible connections

10 x cable diameter

min. bend radius for fixed installations 5 x cable diameter

Application

cables intended for fixed installations in cable ducts, in industrial equipment, production lines, to connect control, safety and control equipment and equipment for transferring electricity in temperate climates, cables are suitable for flexible connections, common shield ensures that the cable is protected from electromagnetic interference and restricts emitting interference outside the cable

Packing

coils, drums

 

YKSLYekwo(żo); YcKSLYekwo(żo); YoKSLYekwo(żo; YnKSLYekwo(żo) 0,6/1 kV

Liczba i przekrój  znamionowy żył

[n x mm2]

Przybliżona średnica zewnętrzna przewodu [mm]

Orientacyjna masa przewodu

[kg/km]

Number and nominal  cross-section of conductor [n x mm2]

Approximate external cable diameter [mm]

Approximate cable weight 

[kg/km]

2 x 0,5

6,3

40

3 x 0,5

6,7

42

4 x 0,5

6,9

45

5 x 0,5

7,5

45

6 x 0,5

8,0

56

7 x 0,5

8,6

68

8 x 0,5

9,1

70

10 x 0,5

9,8

75

12 x 0,5

10,6

84

14 x 0,5

11,4

99

16 x 0,5

11,7

110

20 x 0,5

12,7

147

21 x 0,5

13,3

152

25 x 0,5

14,4

156

32 x 0,5

16,3

167

34 x 0,5

16,8

176

37 x 0,5

17,2

182

40 x 0,5

18,2

188

42 x 0,5

18,6

193

50 x 0,5

19,1

196

2 x 0,75

8,3

97

3 x 0,75

8,4

100

4 x 0,75

9,7

126

5 x 0,75

10,2

144

6 x 0,75

11,1

162

7 x 0,75

11,9

183

8 x 0,75

12,1

241

10 x 0,75

14,0

255

12 x 0,75

14,4

285

14 x 0,75

15,1

322

16 x 0,75

15,8

355

20 x 0,75

18,0

449

21 x 0,75

18,3

471

25 x 0,75

20,2

525

32 x 0,75

20,9

576

34 x 0,75

21,6

608

37 x 0,75

23,8

712

40 x 0,75

24,2

769

42 x 0,75

25,9

822

50 x 0,75

27,0

931

2 x 1

8,5

89

3 x 1

8,9

109

4 x 1

10,2

145

5 x 1

10,9

163

6 x 1

11,8

190

 

 

Warianty / Variants (900)

IDWariantSymbolPDF
12705PARCONTROL YnKSLYekwo żo 7 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12706PARCONTROL YnKSLYekwo żo 8 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12707PARCONTROL YnKSLYekwo żo 10 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12708PARCONTROL YnKSLYekwo żo 12 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12709PARCONTROL YnKSLYekwo żo 14 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12710PARCONTROL YnKSLYekwo żo 16 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12711PARCONTROL YnKSLYekwo żo 20 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12712PARCONTROL YnKSLYekwo żo 21 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12713PARCONTROL YnKSLYekwo żo 25 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12714PARCONTROL YnKSLYekwo żo 32 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12715PARCONTROL YnKSLYekwo żo 34 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12716PARCONTROL YnKSLYekwo żo 37 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12717PARCONTROL YnKSLYekwo żo 40 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12718PARCONTROL YnKSLYekwo żo 42 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12719PARCONTROL YnKSLYekwo żo 50 x 1 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12720PARCONTROL YnKSLYekwo żo 3 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12721PARCONTROL YnKSLYekwo żo 4 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12722PARCONTROL YnKSLYekwo żo 5 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12723PARCONTROL YnKSLYekwo żo 6 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12724PARCONTROL YnKSLYekwo żo 7 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12725PARCONTROL YnKSLYekwo żo 8 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12726PARCONTROL YnKSLYekwo żo 10 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12727PARCONTROL YnKSLYekwo żo 12 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12728PARCONTROL YnKSLYekwo żo 14 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12729PARCONTROL YnKSLYekwo żo 16 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12730PARCONTROL YnKSLYekwo żo 20 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12731PARCONTROL YnKSLYekwo żo 21 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12732PARCONTROL YnKSLYekwo żo 25 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12733PARCONTROL YnKSLYekwo żo 32 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12734PARCONTROL YnKSLYekwo żo 34 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12735PARCONTROL YnKSLYekwo żo 37 x 1,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12736PARCONTROL YnKSLYekwo żo 3 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12737PARCONTROL YnKSLYekwo żo 4 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12738PARCONTROL YnKSLYekwo żo 5 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12739PARCONTROL YnKSLYekwo żo 6 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12740PARCONTROL YnKSLYekwo żo 7 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12741PARCONTROL YnKSLYekwo żo 8 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12742PARCONTROL YnKSLYekwo żo 10 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12743PARCONTROL YnKSLYekwo żo 12 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12744PARCONTROL YnKSLYekwo żo 14 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12745PARCONTROL YnKSLYekwo żo 16 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12746PARCONTROL YnKSLYekwo żo 20 x 2,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo(żo) 0,6/1 kV
12747PARCONTROL YKSLYekwo-P 2 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12748PARCONTROL YKSLYekwo-P 3 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12749PARCONTROL YKSLYekwo-P 4 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12750PARCONTROL YKSLYekwo-P 5 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12751PARCONTROL YKSLYekwo-P 6 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12752PARCONTROL YKSLYekwo-P 7 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12753PARCONTROL YKSLYekwo-P 8 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV
12754PARCONTROL YKSLYekwo-P 10 x 2 x 0,5 0,6/1kVPARCONTROL Y(o,c,n)KSLYekwo-P 0,6/1 kV

Wydruk obejmuje opis rodziny i widoczną stronę wariantów. Pełny zestaw można przeglądać kolejnymi stronami.