PARCONTROL YKSLY(żo), YcKSLY(żo), YoKSLY(żo), YnKSLY(żo), YvKSLY(żo), YKSLY-P, YcKSLY-P, YoKSLY-P, YnKSLY-P, YvKSLY-P 300/500 V

PARCONTROL YKSLY(żo), YcKSLY(żo), YoKSLY(żo), YnKSLY(żo), YvKSLY(żo), YKSLY-P, YcKSLY-P, YoKSLY-P, YnKSLY-P, YvKSLY-P 300/500 V

Control (S) cable (K) with copper multi-wire conductors (L) in softened PVC insulation (Y) and softened PVC sheath (Y), with green and yellow protective conductor (żo) or without green and yellow protective conductor (żo) or with paired conductors (P).

CONSTRUCTION:

Conductors

copper, multi-wire, class 5 as per PN-EN 60228

Insulation

special softened PVC

Central core

PARCONTROL YKSLY(żo) – conductors stranded into a central core

PARCONTROL YKSLY-P – conductors stranded into pairs, pairs stranded into a central core

Sheath

PARCONTROL YKSLY(żo) – special softened PVC (Y), black

PARCONTROL YcKSLY(żo) – special heat resistant softened PVC (Yc)

PARCONTROL YoKSLY(żo) – special oil resistant softened PVC (Yo), as per PN-EN 60811-404:2012 PARCONTROL YnKSLY(żo) – special softened PVC with increased fire resistance and oxygen index of at least 29 (Yn)

PARCONTROL YvKSLY(żo) – special heavy duty softened PVC (Yv)

Insulation colours

all conductors black with white numbers, in case there is a green and yellow protective conductor – it is marked with green and yellow colour and located in the external layer

Operating temperature

-30°C to +70°C

Nominal voltage

300/500 V

Bend radius

min. bend radius for flexible connections

7,5 x cable diameter

min. bend radius for fixed installations 4 x cable diameter

Application

cables intended for fixed installations in cable ducts, in industrial equipment, production lines, to connect control, safety and control equipment and equipment for transferring electricity in

temperate climates, cables are suitable for flexible connections

Packing

coils, drums

 

PARCONTROL YKSLY(żo) 300/500 V

Liczba i przekrój  znamionowy żył

[n x mm2]

Przybliżona średnica zewnętrzna przewodu [mm]

Orientacyjna masa przewodu

[kg/km]

Number and nominal  cross-section of conductor [n x mm2]

Approximate external cable diameter [mm]

Approximate cable weight 

[kg/km]

2 x 0,75

5,9

50

2 x 1

6,2

57

2 x 1,5

7,2

78

2 x 2,5

8,3

109

3 x 0,75

6,5

60

3 x 1

6,9

69

3 x 1,5

8

95

3 x 2,5

9,7

143

4 x 0,75

7,4

75

4 x 1

7,7

87

4 x 1,5

8,8

115

4 x 2,5

10,6

174

6 x 0,75

8,7

105

6 x 1

9,1

124

6 x 1,5

10,8

176

6 x 2,5

12,8

257

7 x 0,75

8,7

110

7 x 1

9,1

130

7 x 1,5

10,8

185

7 x 2,5

12,8

271

8 x 0,75

10

128

8 x 1

10,5

150

8 x 1,5

12,2

207

8 x 2,5

14,3

301

10 x 0,75

11,3

152

10 x 1

12,2

184

10 x 1,5

13,9

247

1 0 x 2 5

16,8

376

12 x 0,75

11,7

174

12 x 1

12,5

211

12 x 1,5

14,5

291

1 2 x 2 5

17,3

434

14 x 0,75

12,5

203

14 x 1

13,2

240

14 x 1,5

15,2

331

1 4 x 2,5

18,2

494

16 x 0,75

13,1

230

Warianty / Variants (908)

IDWariantSymbolPDF
7406PARCONTROL YnKSLY-P 14 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7407PARCONTROL YnKSLY-P 14 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7408PARCONTROL YnKSLY-P 14 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7409PARCONTROL YnKSLY-P 14 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7410PARCONTROL YnKSLY-P 16 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7411PARCONTROL YnKSLY-P 16 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7412PARCONTROL YnKSLY-P 16 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7413PARCONTROL YnKSLY-P 16 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7414PARCONTROL YnKSLY-P 16 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7415PARCONTROL YnKSLY-P 18 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7416PARCONTROL YnKSLY-P 18 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7417PARCONTROL YnKSLY-P 18 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7418PARCONTROL YnKSLY-P 20 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7419PARCONTROL YnKSLY-P 24 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7420PARCONTROL YvKSLY-P 2 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7421PARCONTROL YvKSLY-P 2 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7422PARCONTROL YvKSLY-P 2 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7423PARCONTROL YvKSLY-P 2 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7424PARCONTROL YvKSLY-P 2 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7425PARCONTROL YvKSLY-P 3 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7426PARCONTROL YvKSLY-P 3 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7427PARCONTROL YvKSLY-P 3 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7428PARCONTROL YvKSLY-P 3 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7429PARCONTROL YvKSLY-P 3 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7430PARCONTROL YvKSLY-P 4 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7431PARCONTROL YvKSLY-P 4 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7432PARCONTROL YvKSLY-P 4 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7433PARCONTROL YvKSLY-P 4 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7434PARCONTROL YvKSLY-P 4 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7435PARCONTROL YvKSLY-P 5 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7436PARCONTROL YvKSLY-P 5 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7437PARCONTROL YvKSLY-P 5 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7438PARCONTROL YvKSLY-P 5 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7439PARCONTROL YvKSLY-P 5 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7440PARCONTROL YvKSLY-P 7 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7441PARCONTROL YvKSLY-P 7 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7442PARCONTROL YvKSLY-P 7 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7443PARCONTROL YvKSLY-P 7 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7444PARCONTROL YvKSLY-P 10 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7445PARCONTROL YvKSLY-P 10 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7446PARCONTROL YvKSLY-P 10 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7447PARCONTROL YvKSLY-P 10 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7448PARCONTROL YvKSLY-P 10 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7449PARCONTROL YvKSLY-P 14 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7450PARCONTROL YvKSLY-P 14 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7451PARCONTROL YvKSLY-P 14 x 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7452PARCONTROL YvKSLY-P 14 x 2 x 1,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7453PARCONTROL YvKSLY-P 14 x 2 x 2,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7454PARCONTROL YvKSLY-P 16 x 2 x 0,5 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V
7455PARCONTROL YvKSLY-P 16 x 2 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLY-P 300/500 V

Wydruk obejmuje opis rodziny i widoczną stronę wariantów. Pełny zestaw można przeglądać kolejnymi stronami.