PARCONTROL YKSLYekwo(żo), YcKSLYekwo(żo), YoKSLYekwo(żo), YnKSLYekwo(żo), YvKSLYekwo(żo), YKSLYekwo-P, YcKSLYekwo-P, YoKSLYekwo-P, YnKSLYekwo-P, YvKSLYekwo-P 300/500 V

PARCONTROL YKSLYekwo(żo), YcKSLYekwo(żo), YoKSLYekwo(żo), YnKSLYekwo(żo), YvKSLYekwo(żo), YKSLYekwo-P, YcKSLYekwo-P, YoKSLYekwo-P, YnKSLYekwo-P, YvKSLYekwo-P 300/500 V

Signal (S) cable (K) with copper multi-wire conductors (L) in softened PVC insulation (Y) and softened PVC sheath (Y), with common shield in the form of a braid of copper wires (ekwo), with green and yellow protective conductor (żo) or without green and yellow protective conductor (żo) or with paired conductors (P).

CONSTRUCTION:

Conductors

copper, multi-wire, class 5 as per PN-EN 60228

Insulation

special softened PVC

Central core

PARCONTROL YKSLYekwo(żo) – conductors stranded into a central core

PARCONTROL YKSLYekwo-P – conductors stranded into pairs, pairs stranded into a central core

Shield

with common shield on central core in the form of a braid of copper wires

Sheath

PARCONTROL YKSLYekwo(żo) – special softened

PVC (Y), UV resistant, black

PARCONTROL YcKSLYekwo(żo) – special heat resistant softened PVC (Yc)

PARCONTROL YoKSLYekwo(żo) – oil resistant softened PVC, as per PN-EN 60811-404:2012 (Yo) PARCONTROL YnKSLYekwo(żo) – special softened PVC with increased fire resistance and oxygen index of at least 29 (Yn)

Insulation colours

all conductors black with white numbers, in case there is a protective conductor – it is marked with green and yellow colour and located in the external layer

Operating temperature

-30°C to +70°C

Nominal voltage

300/500 V

Bend radius

min. bend radius for flexible connections

10 x cable diameter

min. bend radius for fixed installations 5 x cable diameter

Application

cables intended for fixed installations in cable ducts, in industrial equipment, production lines, to connect control, safety and control equipment and equipment for transferring electricity in temperate climates, common shield ensures that the cable is protected from electromagnetic interference and restricts emitting interference outside the cable

Packing

coils, drums

 

PARCONTROL YKSLYekwo(żo) 300/500 V

Liczba i przekrój  znamionowy żył

[n x mm2]

Przybliżona średnica zewnętrzna przewodu [mm]

Orientacyjna masa przewodu

[kg/km]

Number and nominal  cross-section of conductor [n x mm2]

Approximate external cable diameter [mm]

Approximate cable weight 

[kg/km]

2 x 0,75

6,5

62

2 x 1

7

71

2 x 1,5

7,8

92

2 x 2,5

9,3

129

3 x 0,75

7

73

3 x 1

7,3

84

3 x 1,5

8,2

106

3 x 2,5

9,8

151

4 x 0,75

7,6

90

4 x 1

8

101

4 x 1,5

9,3

137

4 x 2,5

10,7

186

5 x 0,75

8,2

105

5 x 1

8,6

120

5 x 1,5

10,1

165

5 x 2,5

11,8

235

6 x 0,75

9,3

130

6 x 1

9,7

151

6 x 1,5

10,9

198

6 x 2,5

12,8

277

7 x 0,75

9,3

136

7 x 1

9,7

157

7 x 1,5

10,9

207

7 x 2,5

12,8

291

8 x 0,75

10,1

157

8 x 1

10,6

180

8 x 1,5

12,2

243

8 x 2,5

14,3

343

10 x 0,75

11,6

194

10 x 1

12,2

221

10 x 1,5

14

294

10 x 2,5

16,6

425

12 x 0,75

11,9

216

12 x 1

12,5

249

12 x 1,5

14,4

333

12 x 2,5

17,1

485

14 x 0,75

12,5

240

14 x 1

13,1

278

14 x 1,5

15,1

376

14 x 2,5

18,3

574

16 x 0,75

13,1

267

16 x 1

14

319

16 x 1,5

16,3

437

16 x 2,5

19,3

646

20 x 0,75

14,6

333

20 x 1

15,4

390

20 x 1,5

18,3

559

20 x 2,5

21,4

801

21 x 0,75

14,6

337

21 x 1

15,4

396

21 x 1,5

18,3

565

21 x 2,5

21,4

817

25 x 0,75

16,8

419

25 x 1

17,9

508

25 x 1,5

20,6

683

25 x 2,5

24,2

981

32 x 0,75

18,4

526

32 x 1

19,4

622

32 x 1,5

21,5

774

34 x 0,75

17,6

586

34 x 1

18,3

698

34 x 1,5

22,6

875

37 x 0,75

26,6

983

37 x 1

28,0

1123

37 x 1,5

30,1

1372

40 x 0,75

28,5

1095

40 x 1

21

1294

42 x 0,75

29,8

1154

50 x 0,75

30,9

1324

50 x 1

32,1

1479

 

PARCONTROL YKSLYekwo-P 300/500 V

Ilość par x przekrój znamionowy żył

[n x 2 x mm2]

Przybliżona średnica zewnętrzna przewodu [mm]

Orientacyjna masa przewodu

[kg/km]

Number of pairs x nominal cross-section of conductor [n x 2 x mm2]

Approximate externalcable diameter [mm]

Approximate cable weight 

[kg/km]

2 x 2 x 0,5

7,8

85

2 x 2 x 0,75

9,5

118

2 x 2 x 1

10

135

2 x 2 x 1,5

11,4

180

2 x 2 x 2,5

13,4

245

3 x 2 x 0,5

9,1

105

3 x 2 x 0,75

10,6

140

3 x 2 x 1

11,3

165

3 x 2 x 1,5

12,8

207

3 x 2 x 2,5

15

290

4 x 2 x 0,5

9,8

123

4 x 2 x 0,75

11,6

173

4 x 2 x 1

12,2

196

4 x 2 x 1,5

14,1

260

4 x 2 x 2,5

16,7

373

5 x 2 x 0,5

10,5

148

5 x 2 x 0,75

12,5

208

5 x 2 x 1

13,4

244

5 x 2 x 1,5

15,2

319

5 x 2 x 2,5

18,4

483

6 x 2 x 0,5

10,8

164

7 x 2 x 0,5

12,3

191

7 x 2 x 0,75

14,6

264

7 x 2 x 1

15,8

320

7 x 2 x 1,5

18,4

441

7 x 2 x 2,5

21,6

620

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 x 2 x 0,5

12,8

208

10 x 2 x 0,5

13,9

250

10 x 2 x 0,75

16,7

358

10 x 2 x 1

18,1

438

10 x 2 x 1,5

20,5

56

10 x 2 x 2,5

24,6

840

12 x 2 x 0,5

14,7

285

12 x 2 x 0,75

18,2

433

12 x 2 x 1

19,2

502

12 x 2 x 1,5

22,1

673

12 x 2 x 2,5

26,2

971

14 x 2 x 0,5

16

336

14 x 2 x 0,75

19,3

487

14 x 2 x 1

20,4

566

14 x 2 x 1,5

23,4

761

14 x 2 x 2,5

27,8

1103

16 x 2 x 0,5

17,3

393

16 x 2 x 0,75

20,6

551

16 x 2 x 1

21,9

652

16 x 2 x 1,5

25,5

890

16 x 2 x 2,5

29,8

1257

18 x 2 x 0,5

18,2

432

18 x 2 x 0,75

21,6

604

18 x 2 x 1

22,9

7,5

20 x 2 x 0,5

18,9

468

24 x 2 x 0,5

19,5

532

Warianty / Variants (940)

IDWariantSymbolPDF
8212PARCONTROL YKSLYekwo 2 x 0, 75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8213PARCONTROL YKSLYekwo 2 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8214PARCONTROL YKSLYekwo 2 x 1 ,5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8215PARCONTROL YKSLYekwo 2 x 2 ,5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8216PARCONTROL YKSLYekwo 3 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8217PARCONTROL YKSLYekwo 3 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8218PARCONTROL YKSLYekwo 3 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8219PARCONTROL YKSLYekwo 3 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8220PARCONTROL YKSLYekwo 4 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8221PARCONTROL YKSLYekwo 4 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8222PARCONTROL YKSLYekwo 4 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8223PARCONTROL YKSLYekwo 4 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8224PARCONTROL YKSLYekwo 5 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8225PARCONTROL YKSLYekwo 5 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8226PARCONTROL YKSLYekwo 5 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8227PARCONTROL YKSLYekwo 5 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8228PARCONTROL YKSLYekwo 6 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8229PARCONTROL YKSLYekwo 6 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8230PARCONTROL YKSLYekwo 6 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8231PARCONTROL YKSLYekwo 6 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8232PARCONTROL YKSLYekwo 7 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8233PARCONTROL YKSLYekwo 7 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8234PARCONTROL YKSLYekwo 7 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8235PARCONTROL YKSLYekwo 7 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8236PARCONTROL YKSLYekwo 8 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8237PARCONTROL YKSLYekwo 8 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8238PARCONTROL YKSLYekwo 8 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8239PARCONTROL YKSLYekwo 8 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8240PARCONTROL YKSLYekwo 10 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8241PARCONTROL YKSLYekwo 10 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8242PARCONTROL YKSLYekwo 10 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8243PARCONTROL YKSLYekwo 10 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8244PARCONTROL YKSLYekwo 12 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8245PARCONTROL YKSLYekwo 12 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8246PARCONTROL YKSLYekwo 12 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8247PARCONTROL YKSLYekwo 12 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8248PARCONTROL YKSLYekwo 14 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8249PARCONTROL YKSLYekwo 14 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8250PARCONTROL YKSLYekwo 14 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8251PARCONTROL YKSLYekwo 14 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8252PARCONTROL YKSLYekwo 16 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8253PARCONTROL YKSLYekwo 16 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8254PARCONTROL YKSLYekwo 16 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8255PARCONTROL YKSLYekwo 16 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8256PARCONTROL YKSLYekwo 20 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8257PARCONTROL YKSLYekwo 20 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8258PARCONTROL YKSLYekwo 20 x 1, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8259PARCONTROL YKSLYekwo 20 x 2, 5 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8260PARCONTROL YKSLYekwo 21 x 0,75 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V
8261PARCONTROL YKSLYekwo 21 x 1 300/500VPARCONTROL Y(c,o,n,v)KSLYekwo(żo) 300/500 V

Wydruk obejmuje opis rodziny i widoczną stronę wariantów. Pełny zestaw można przeglądać kolejnymi stronami.